Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Imaging Sci Dent ; 54(1): 49-56, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571773

RESUMO

Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR (P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38553310

RESUMO

OBJECTIVE: This study aimed to assess the performance of a convolutional neural network (CNN) model in detecting the pubertal growth spurt by analyzing cervical vertebrae maturation (CVM) in lateral cephalometric radiographs (LCRs). STUDY DESIGN: In total, 600 LCRs of patients from 6 to 17 years old were selected. Three radiologists independently and blindly classified the maturation stages of the LCRs and defined the difficulty of each classification. Subsequently, the stage and level of difficulty were determined by consensus. LCRs were distributed between training, validation, and test datasets across 4 CNN-based models. The models' responses were compared with the radiologists' reference standard, and the architecture with the highest success rate was selected for evaluation. Models were developed using full and cropped LCRs with original and simplified maturation classifications. RESULTS: In the simplified classification, the Inception-v3 CNN yielded an accuracy of 74% and 75%, with recall and precision values of 61% and 62%, for full and cropped LCRs, respectively. It achieved 61% and 62% total success rates with full and cropped LCRs, respectively, reaching 72.7% for easy-to-classify cropped cases. CONCLUSION: Overall, the CNN model demonstrated potential for determining the maturation status regarding the pubertal growth spurt through images of the cervical vertebrae. It may be useful as an initial assessment tool or as an aid for optimizing the assessment and treatment decisions of the clinician.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38365543

RESUMO

OBJECTIVE: To assess the accuracy and reproducibility of cephalometric landmark identification performed by 2 artificial intelligence (AI)-driven applications (CefBot and WebCeph) and human examiners. STUDY DESIGN: Lateral cephalometric radiographs of 10 skulls containing 0.5 mm lead spheres directly placed at 10 cephalometric landmarks were obtained as the reference standard. Ten radiographs without spheres were obtained from the same skulls for identification of cephalometric points performed by the AI applications and 10 examiners. The x- and y-coordinate values of the cephalometric points identified by the AI applications and examiners were compared with those from the reference standard images using one-way analysis of variance and the Dunnet post-hoc test. The intraclass correlation coefficient (ICC) was used to evaluate reproducibility. Mean radial error (MRE) in identification was calculated with respect to the reference standard. Statistical significance was established at P < .05. RESULTS: Landmark identification by CefBot and the examiners did not exhibit significant differences from the reference standard on either axis (P > .05). WebCeph produced a significant difference (P < .05) in 4 and 6 points on the x- and y-axes, respectively. Reproducibility was excellent for CefBot and the examiners (ICC ≥ 0.9943) and good for WebCeph (ICC ≥ 0.7868). MREs of CefBot and the examiners were similar. CONCLUSION: With results similar to those of human examiners, CefBot demonstrated excellent reliability and can aid in cephalometric applications. WebCeph produced significant errors.


Assuntos
Inteligência Artificial , Crânio , Humanos , Reprodutibilidade dos Testes , Cefalometria/métodos , Radiografia
4.
Dentomaxillofac Radiol ; 53(2): 153-160, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38224272

RESUMO

OBJECTIVES: To evaluate the effect of the presence and the number of high-density objects in the exomass on the volume of a high-density object in cone-beam CT (CBCT). METHODS: Cylinders of cobalt-chromium (Co-Cr), titanium (Ti), and zirconium (Zi) were inserted into a polymethylmethacrylate phantom in five different combinations of number and position: 1-no cylinder; 2-one cylinder in a posterior region; 3-one cylinder in an anterior region; 4-two cylinders in posterior regions; and 5-three cylinders in anterior and posterior regions. The phantom underwent CBCT scanning using OP300 and X800 systems, with the afore mentioned cylinders of the same composition placed in the exomass and an additional high-density cylinder placed in the centre of the field of view (FOV), corresponding to the left-anterior region. The tomographic volume of the cylinder inside the FOV was measured using semi-automatic segmentation. The volumetric alteration (VA) between the segmented and physical volumes, in percentage, was compared among the experimental groups using repeated measures ANOVA and Tukey post-hoc (α = 5%). RESULTS: The factors material, combination, and their interaction affected the volume or both CBCT systems. In OP300, more cylinders in the exomass reduced the VA, mainly for Co-Cr. In X800, more cylinders in the exomass tended to increase the VA inside the FOV, except for Zi. CONCLUSIONS: In general, the presence of high-density objects in the exomass influences the VA of the object inside the FOV, although this oscillates according to object composition, number and position in the exomass, and CBCT system.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas
5.
Odontology ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38214844

RESUMO

This study aimed to evaluate the influence of the metal post composition, tooth location in the dental arch, and metal artifact reduction (MAR) on vertical root fracture (VRF) diagnosis in cone beam computed tomography (CBCT). Twenty-two unirradicular premolars (12 sound and 10 fractured) and two alveolar sockets of a mandible (anterior and posterior regions) composed the sample. CBCT scans of each tooth with a metal post placed into the root canal-silver-palladium (Ag-Pd), cobalt-chromium (Co-Cr), or nickel-chromium (Ni-Cr)-were individually acquired for each mandibular region, and two conditions of MAR, using a OP300 device (Instrumentarium, Finland). Images were assessed by five evaluators independently for VRF detection. Diagnostic values were calculated and compared among all groups using multi-way ANOVA with Tukey post hoc test to investigate the effect of post material, anatomical region, and MAR on VRF diagnosis (α = 0.05). Values of area under the receiver operating curve and specificity were not influenced by the studied factors (p > 0.05). Sensitivity was influenced by the MAR in both mandibular regions (p < 0.05). In the anterior region, sensitivity values increased when the MAR was enabled, regardless of the metal post material (p < 0.05). Similar behavior was noticed in the posterior region for Ni-Cr (p < 0.05) but not for Ag-Pd and Co-Cr posts (p > 0.05). The MAR improved the sensitivity in VRF diagnosis for all tested metal posts in the mandibular anterior region and for the Ni-Cr post in the mandibular posterior region. Therefore, for images obtained in the OP300 CBCT device, activation of the MAR is suggested in these cases.

6.
Artigo em Inglês | MEDLINE | ID: mdl-37940483

RESUMO

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.


Assuntos
Fraturas dos Dentes , Raiz Dentária , Humanos , Raiz Dentária/diagnóstico por imagem , Zircônio , Fraturas dos Dentes/diagnóstico por imagem , Artefatos , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos
7.
J Oral Rehabil ; 51(3): 517-525, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37941125

RESUMO

BACKGROUND: There is no established protocol for the low doses of cone-beam computed tomography (CBCT) acquisition and filter application on the diagnosis of condylar morphological alterations. OBJECTIVES: The objective of the study was to evaluate the influence of voxel size and filter application on the diagnosis of condylar morphological alterations in CBCT using an ex vivo model. METHODS: CBCT scans of 36 temporomandibular joints were acquired using OP300 Maxio with voxel sizes of 0.085, 0.125 and 0.280 mm. Three radiologists evaluated the condyles in the CBCT volumes under three filter modes: no filter, '1x' sharpen filter and '2x' sharpen filter. The area under the ROC curve, sensitivity and specificity were calculated by comparing the evaluators' responses with the reference standard and compared among experimental groups using analysis of variance (ANOVA) (α = 5%). RESULTS: The area under the ROC curve, sensitivity and specificity were not affected by voxel size and filter application (p > .05). For osteophyte and flattening, there were more true-positive responses in smaller voxel size. For erosion, the increase of true- and false-positive responses occurred with a larger voxel size. Overall, there was a tendency to decrease true positives for osteophyte and erosion and increase false positives for flattening with the '2x' sharpen filter. CONCLUSIONS: The diagnosis of condylar morphological alterations assessed in this ex vivo analysis is not influenced by the voxel size and the application of the filters. However, attention is needed with the occurrence of false-positive diagnosis with a larger voxel size for erosion and '2x' sharpen filter for flattening.


Assuntos
Osteófito , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Sensibilidade e Especificidade , Tomografia Computadorizada de Feixe Cônico/métodos , Osso e Ossos
8.
Artigo em Inglês | MEDLINE | ID: mdl-37980244

RESUMO

OBJECTIVE: We investigated the influence of voxel and field of view (FOV) sizes on expression of the volumetric alteration artifact (VAA) of 5 high-density materials in 2 cone beam computed tomography (CBCT) devices. STUDY DESIGN: Cylinders of amalgam, cobalt-chromium, gutta-percha, titanium, and zirconium were individually positioned in a polymethyl methacrylate phantom. OP300 Maxio and ProMax 3D Classic CBCT devices were used to acquire images with varying voxel and FOV sizes, totaling 585 scans. Two evaluators segmented the high-density cylinder images to obtain the tomographic volumes. The difference between the tomographic and physical volume of each cylinder (i.e., volumetric alteration) was calculated. Statistical analysis was conducted with multiway ANOVA and the Tukey post hoc test (α = 5%). Evaluator reliability was measured with the intraclass correlation coefficient (ICC). RESULTS: All studied parameters and nearly all interactions influenced the VAA (P < .05). The post hoc test demonstrated less volumetric alteration for the smallest voxel sizes, 61 × 78 mm FOV, and gutta-percha for OP300, and for the smallest voxel sizes, 80 × 80 mm FOV, and gutta-percha and titanium for ProMax 3D (P < .05). The ICC demonstrated perfect reliability (1.00). CONCLUSIONS: Voxel and FOV sizes influenced VAA expression. Using smaller voxel sizes, the 61 × 78 mm FOV for OP300 and the 80 × 80 mm FOV for ProMax 3D, and materials with lower density and lower atomic number reduced VAA expression.


Assuntos
Artefatos , Guta-Percha , Humanos , Reprodutibilidade dos Testes , Titânio , Tomografia Computadorizada de Feixe Cônico
9.
Artigo em Inglês | MEDLINE | ID: mdl-37838553

RESUMO

OBJECTIVE: We evaluated artifact expression in a root adjacent to a dental implant located in the endomass or exomass in cone beam computed tomography (CBCT). STUDY DESIGN: We placed a single titanium or zirconia implant adjacent to a premolar root in a dried human mandible and acquired CBCT scans using an OP300 Maxio and a Picasso Trio 3D unit exposing a 5x5cm field of view with the implant in the endomass or exomass (implant groups) or without an implant (control group). We measured the mean gray values (MGVs) for 8 lines of interest (LOIs) around the root canal of the premolar and compared the MGVs by analysis of variance, with significance established at P < 0.05. RESULTS: For the OP300 Maxio scans, the MGVs of both implant groups in the endomass were lower than the MGVs of the control group. In the exomass, the titanium group had MGVs similar to the control group, but the zirconia group produced significantly lower MGVs than control and titanium groups (P <.0001), indicating the presence of hypodense artifacts. For the Picasso Trio 3D scans, the MGVs of both implant groups in the endomass were similar to the MGVs of the control group. In the exomass, the zirconia group generated lower MGVs than control and titanium groups (P <.0001), indicating hypodense artifacts. CONCLUSIONS: When performing CBCT examination, titanium implants produce less artifact expression in the exomass, and zirconia implants have less artifact expression in the endomass.


Assuntos
Implantes Dentários , Titânio , Humanos , Artefatos , Zircônio , Tomografia Computadorizada de Feixe Cônico/métodos
10.
Eur J Radiol ; 170: 111210, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38101195

RESUMO

Since previous literatureregarding the application of the metaverse in educationis scarce, the present letter aimed to highlight possible applications, as a complementary tool for the classroom, in the oral and maxillofacial radiology academic experience.Thepotential risksof the metaverse are also discussed. The metaverse and its possible applications, especially related to enhanced teaching and learning, will become a hot topic in the near future, and therefore, there will be a challenging learning curve before the educator makes the most of these innovative educational tools empowered by deeply interactive virtual reality technology.


Assuntos
Radiologia , Realidade Virtual , Humanos , Radiografia , Aprendizagem
11.
Braz Dent J ; 34(4): 150-157, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909638

RESUMO

This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Assuntos
Radiografia Dentária Digital , Radiografia Dentária Digital/métodos
12.
Clin Oral Investig ; 27(11): 6451-6460, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37728617

RESUMO

OBJECTIVES: To compare the multilayer panoramic radiography (MPAN) and conventional panoramic radiography (CPAN) in the evaluation of mandibular third molars using cone-beam computed tomography (CBCT) as a reference. METHODS: CPAN, MPAN, and CBCT scans from 33 dry human mandibles were acquired using the OP300 Maxio unit, totalizing 56 mandibular third molars to be evaluated. Three examiners evaluated each third molar according to their position, depth of impaction in the mandibular ramus, proximity between the dental root apexes and the mandibular canal, and the presence of radiographic signs of proximity to the mandibular canal. In addition, when there was a distance between the root apexes and the mandibular canal, it was measured. As a reference, these same parameters were assessed in the CBCT scans by a fourth examiner. For the statistical analysis, the weighted Kappa, Bland Altman, and Wilcoxon tests were performed (α = 0.05). RESULTS: The agreement between the assessments performed in the panoramic modalities with the CBCT ranged from 66.1% to 100.0% for the categorical variables. Overall, the agreement values of CPAN and MPAN with CBCT were similar. The distances between the dental root apex and the mandibular canal for both CPAN and MPAN were significantly underestimated compared to CBCT (p < 0.05). The intra- and interexaminer agreements of the examiners ranged from poor to almost perfect; in general, the agreements were higher in the evaluation performed in the MPAN than in the CPAN. CONCLUSIONS: The MPAN performs similarly to CPAN for evaluating mandibular third molars and their proximity relationship to the mandibular canal. CLINICAL RELEVANCE: Preoperative evaluation of lower mandibular third molars is usually performed using CPAN. Recently, a new tool, MPAN, was developed, which has not yet been tested for the evaluation of mandibular third molars and showed similar performance to CPAN in the present study. Future studies using MPAN are encouraged to evaluate other diagnostic tasks.


Assuntos
Dente Serotino , Dente Impactado , Humanos , Dente Serotino/cirurgia , Radiografia Panorâmica/métodos , Dente Molar , Mandíbula , Tomografia Computadorizada de Feixe Cônico/métodos
13.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520332

RESUMO

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

14.
Dentomaxillofac Radiol ; 52(7): 20230147, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37493606

RESUMO

OBJECTIVE: To compare cylindrical and convex triangular field-of-views (FOVs) concerning the magnitude of artefacts from high-density materials in cone-beam CT (CBCT). METHODS AND MATERIALS: Cylinders of amalgam, chromium-cobalt, titanium, and zirconia were individually placed in the anterior and posterior regions of a polymethylmethacrylate phantom and scanned using cylindrical and convex triangular FOVs of the Veraview X800 CBCT device. Using the Image J software, 15 square regions of interest (ROIs) were placed in the axial reconstruction around the middle level of the cylinder and at distances of 0.5, 1.0, and 1.5 cm from the centre of the cylinder. Mean grey value and standard deviation of each ROI were averaged for each distance and subtracted from the values of a control ROI to calculate the magnitude of the artefacts by the grey value mean difference (GVMD) and grey value standard deviation (GVSD). Multiway analysis of variance with Tukey post-hoc test with a significance level of 5% evaluated the effect of the shape of the FOV, position inside the FOV, high-density material, and the distance of the artefact from the material. RESULTS: The convex triangular FOV increased the GVSD for all materials in the anterior and posterior regions at 0.5 cm compared to the cylindrical FOV (p < 0.0001). The convex triangular FOV showed greater GVMD for chromium-cobalt and zirconium in the anterior region and all materials in the posterior region at all distances (p < 0.0001). CONCLUSION: The FOV shape influences the magnitude of artefacts from high-density materials. The convex triangular FOV showed greater artefact magnitude with variability among the high-density materials, region in the FOV, and distance from the material.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Cobalto , Cromo , Imagens de Fantasmas
15.
Artigo em Inglês | MEDLINE | ID: mdl-37468380

RESUMO

OBJECTIVE: This study evaluated changes in image quality and the presence and size of artifacts on radiographs obtained with photostimulable phosphor (PSP) plates after disinfection with 70% ethyl alcohol and 70% isopropyl alcohol. STUDY DESIGN: Eight PSP receptors (4 Express and 4 VistaScan) were used for the investigation. Two Express and 2 VistaScan receptors were disinfected with 70% ethyl alcohol, and 2 Express and 2 VistaScan receptors were disinfected with 70% isopropyl alcohol. Before disinfection and after every 5 disinfections, 2 radiographs of an aluminum stepwedge and 2 radiographs of an acrylic block were acquired using each receptor. The gray values of the radiographs were analyzed regarding contrast, density, uniformity, and noise. Four oral radiologists evaluated the images for the presence of artifacts, and 2 measured the artifacts. RESULTS: Differences in image contrast were significantly larger with isopropyl alcohol (P < .0001). Artifact size was significantly greater with the VistaScan system when isopropyl alcohol was used as the disinfectant (P < .0001). The correlation between the number of disinfections and artifact size was moderately positive with the Express system (P < .05) and strongly positive with the VistaScan system (P < .05) with both disinfectants. CONCLUSIONS: Small artifacts restricted to the edges of the image were observed with disinfection using both types of alcohol, and a positive correlation was found between artifact size and the number of disinfections. However, artifacts appeared earlier and of greater size with the VistaScan system when disinfected with 70% isopropyl alcohol. Thus, we recommend using 70% ethyl alcohol to disinfect PSP receptors, with attention placed on its action and evaporation times.


Assuntos
2-Propanol , Radiografia Dentária Digital , Humanos , Radiografia Dentária Digital/métodos , Desinfecção/métodos , Artefatos , Intensificação de Imagem Radiográfica/métodos , Etanol
16.
Restor Dent Endod ; 48(2): e16, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37284345

RESUMO

Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

17.
Clin Oral Investig ; 27(9): 5095-5101, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37380795

RESUMO

OBJECTIVES: To evaluate whether low bone mineral density (BMD) has an association with the presence of head and neck soft tissue calcifications (STC), aging, and impaired mandibular canal cortices visibility. MATERIALS AND METHODS: Panoramic radiographs of 1000 women aged between 50 and 75 years old were evaluated by two examiners to classify BMD using mandibular cortical index (C1- normal, C2-moderately eroded and C3-severely eroded), the presence of STC, and also the mandibular canal cortices visibility at the ramus region. Chi-square test evaluated the association between the variables (α = 5%). RESULTS: There was no association between bone loss and the presence of head and neck soft tissue calcifications, except for calcified thyroid cartilage, which was less visualized at C3 group than others (p < 0.05). Women aged 61 to 70 years old presented higher bone loss than those between 50 and 60 (p < 0.05). The mandibular canal was more poorly visualized at C3 group than C1 and C2 (p < 0.05). CONCLUSIONS: In general, no association between BMD and the presence of STC was found. However, greater bone loss had a positive correlation with aging and impaired mandibular canal cortices visibility. CLINICAL RELEVANCE: No relationship between bone mineral density and the existence of soft tissue calcifications was found. Nevertheless, increased bone loss was positively associated with aging and a reduced mandibular canal cortices visibility. This finding highlights the clinical importance of considering bone density factors when planning treatment strategies for patients with related disorders.


Assuntos
Doenças Ósseas Metabólicas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Densidade Óssea , Radiografia Panorâmica , Calcificação Fisiológica , Mandíbula/diagnóstico por imagem
18.
BMC Oral Health ; 23(1): 361, 2023 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-37271800

RESUMO

BACKGROUND: Since the muscles of chewing are involved in the region of the mandibular angle, important structures in surgical and orthodontic procedures, to study its morphological aspects and the possible influence of different patterns of skeletal development would be of interest. Thus, this study aimed to assess the influence of patient characteristics - such as sex, skeletal malocclusion (Class I, Class II, and Class III) and facial type (brachycephalic, mesocephalic, and dolichocephalic) - on the width, height, thickness, and volume of the mandibular angle, using cone-beam computed tomography (CBCT) scans. METHODS: CBCT scans were assessed - 144 men and 154 women, total of 298 - and classified according to skeletal patterns (skeletal malocclusions and facial types). Width, height, and thickness of the mandibular angle were measured using OnDemand 3D software. The volumetric measures of the mandibular angle were obtained using the ITK-SNAP software. Analysis of Variance (multiway ANOVA) with Tukey's post-hoc test compared the data, with a 5% significance level. RESULTS: Among the factors studied, sex significantly influenced all the analyzed variables (height, width, thickness, and volume of the mandibular angle) (p < 0.05); in general, male individuals presented higher values than females. In some cases, the skeletal malocclusion and facial type factors influenced only the width and height variables (p < 0.05); in general, the Class III and dolichocephalic individuals presented higher values in relation to the other types of skeletal malocclusions and facial types. CONCLUSIONS: Variations in the craniofacial growth pattern, considering the different skeletal malocclusions and facial types, had some influence in the width and height dimensions of the mandibular angle. Furthermore, sex influenced all the studied variables.


Assuntos
Má Oclusão Classe III de Angle , Má Oclusão , Humanos , Masculino , Feminino , Estudos Retrospectivos , Mandíbula/diagnóstico por imagem , Má Oclusão/diagnóstico por imagem , Face/diagnóstico por imagem , Face/anatomia & histologia , Tomografia Computadorizada de Feixe Cônico/métodos , Má Oclusão Classe III de Angle/diagnóstico por imagem , Cefalometria/métodos
19.
Imaging Sci Dent ; 53(1): 61-67, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37006786

RESUMO

Purpose: The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods: Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test (α=0.05). Results: The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions (P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non-ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas (P>0.05). Conclusion: The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.

20.
Dentomaxillofac Radiol ; 52(4): 20220370, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36988093

RESUMO

OBJECTIVE: To assess the subjective image quality of original and manually enhanced radiographs acquired at different X-ray exposure times and using different digital systems. METHODS: A total of 500 radiographs obtained under 10 exposure times, 5 digital systems, and 2 enhancement conditions were assessed by 5 observers, who were asked to categorize each radiograph into acceptable or unacceptable. A radiograph was considered to be acceptable when at least four out of five observers found it acceptable. Descriptive analysis was used to summarize the outcomes and compare the subjective image quality of original and manually enhanced digital radiographs among different X-ray exposure times and digital systems. RESULTS: Express had six exposure times producing acceptable original images within a range from 0.063 to 0.4 s, followed by Digora Toto, which had five within a range from 0.063 to 0.32 s, Digora Optime, which had four within a range from 0.063 to 0.2 s,and SnapShot and VistaScan, which had 2 (0.2 and 0.32 s) and 1 (0.63 s), respectively. Image enhancement turned unacceptable images into acceptable ones in four digital systems: SnapShot at three exposure times, Digora Toto at two exposure times, Express at one exposure time, and VistaScan at four exposure times. CONCLUSION: Image enhancement based on brightness and/or contrast adjustments may be necessary to reveal the useful dynamic range of some digital radiographic systems and PSP-based systems may not necessarily have a wider range than sensor-based systems.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Humanos , Radiografia Dentária Digital/métodos , Intensificação de Imagem Radiográfica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...